             Inlet Collection Efficiency : 
            | 
           
             Meets EPA's PM-10 Reference Method 
              Appendix J to Part 50
            | 
        
         
          |  
             Flow rate :
            | 
           
             40 cfm (adjustable) (1.02 to 1.24 m3)
            | 
        
         
          |  
             Filter medial :  
            | 
           
             Micro-Quartz filter media 8"x 10"for PM10 
              (TE-QMA)
            | 
        
         
          |  
             Flow control :
            | 
           
             MFC (TE-300-310) 
            | 
        
         
          |  
             Motor blower
            | 
           
             2-stage vacuum 0.6 HP  
              110v/60hz (TE-116311) 
              220v/50hz (TE-116312) 
                      
            | 
        
         
          |  
             Flow Indicator :
            | 
           
             Flow / pressure recorder (TE-5009) with TE-106 Charts
            | 
        
         
          |  
             Mechanical programmable timer :
            | 
           
             7-day mechanical timer (TE-5007)
            | 
        
         
          |  
             Elapsed time indicator device :
            | 
           
             Elapsed time indicator (TE-5012)
            | 
        
         
          |  
             Shipping Information :
            | 
           
             
            | 
        
         
          |  
                   Size :
            | 
           
             22.5"x 20"x 45.5" sampler carton 
              32"x 32"x 25.5" inlet carton
            | 
        
         
          |  
                   Weight :
            | 
           
             65 lbs. - sampler carton
            | 
        
         
          |  
             Assembled Space Requirement :
            | 
           
             60 lbs. - inlet carton 
              30"round x 64"high
            | 
        
         
          |  
             Power Requirement   
            | 
           
             Single phase with earth ground 
              110v/60hz or 220v/50hz
            | 
        
         
          |  
             Motor Specifications :
            | 
           
             110v/60hz - Part #TE-116311, 2-stage vacuum 0.6 
              HP, 
              double ball bearing thru-flow discharge 
              220v/50hz - Part #TE-116312, 2-stage vaccum 0.6 HP, 
              ball/sleeve bearing thru-flow discharge
            | 
        
         
          |  
             Altitude Application : 
            | 
           
             to 10,000 feet above sea level
            | 
        
         
          |  
             Ambient Temperature Application : 
            | 
           
             -30 to + 50
            | 
        
         
          |  
             Relative Humidity Application : 
            | 
           
             0 - 100%
            | 
        
         
          |  
             Sample Delay Start Range :
            | 
           
             0 - 7 days
            | 
        
         
          |  
             Start up amps :
            | 
           
             12 amps
            | 
        
         
          |  
             Running amps :
            | 
           
             4 amps
            |